Our
escape gate made of stainless steel with integrated anti-panic function and electric door guard with acoustic warning signal is the ideal solution for
safety and reliability in escape and rescue routes. Developed to meet the highest requirements, it combines functional safety with modern design and flexibility of use.
The escape gate with vertical struts impresses with the following features:
Escape gate for regulated evacuation routes
Made of durable stainless steel round tube (Ø 42x2 mm, quality 1.4301)
Widths and heights available in defined standard dimensions
Flexible installation with tube uprights for floor or wall mounting
With 3 design variants
Standard version: Anti-panic function with door guard in accordance with DIN EN 179
Cost-effective version: only with anti-panic function, without door guard (see options)
Optional with anti-panic and splash-proof door guard (see options)
On request, the gate can be equipped with handles on both sides
The door guard is designed in accordance with DIN EN 179
Image: With vertical struts.
Our gate, made of durable stainless steel round tube (Ø 42x2 mm, quality 1.4301), combines stability with an attractive design. You have a choice of three versions:
with knee strap,
with filler panel or with vertical struts. Flexible mounting options allow it to be
attached to floor or wall uprights. The 1000 mm width is suitable for up to 20 people, while the 1200 mm
width is designed for up to 200 people. On request, the widths can also be customised to meet individual requirements.
For use in escape and rescue routes, the escape gate is equipped
as standard with an anti-panic function and a door guard in accordance with DIN EN 179. The anti-panic function allows the gate
to be opened immediately by simply pressing the handle, even when
locked. The electric door guard emits an acoustic warning signal in the
event of unauthorised opening. Two additional variants are also
available: a reduced version with anti-panic function without door guard
and a splash-proof variant with door guard for damp areas of
application.
For user-friendly operation, the door is
equipped with a handle on one side and a knob on the other as standard, with the
door guard providing additional security in accordance with
DIN EN 179.
The EltVTR regulations do not need to be taken into account here. On
request, the door can be fitted with handles on both sides.
Important to note: To ensure maximum safety and compliance with all relevant regulations, the projected door width must be planned in consultation with the building owner and the fire protection authorities, taking ASR A2.3 into account. This ensures compliance with all relevant safety regulations.